• 6604cbdw26
  • 6604cbdkqo
  • 6604cbdzun
  • 6604cbdw9j
  • 6604cbdhwo
Leave Your Message

Charging Module 30kw 40kw AC DC Power Supply Converter DC Power Module

30kw charger is the inner power module for DC charging stations (piles), and convert AC energy into DC in order to charge vehicles.

1,It takes a 3-phase current input and then outputs the DC voltage as 200VDC-500VDC/300VDC-750VDC/150VDC-1000VDC, with an adjustable DC output to meet a variety of battery pack requirements.

2,It is equipped with a POST (power on self-test) function, AC input over/under voltage protection, output over voltage protection, over-temperature protection and other features. Users can connect multiple charger modules in a parallel manner to one power supply cabinet, and we guarantee that our connect multiple EV chargers are highly reliable, applicable, efficient, and require very little maintenance.

3,It has prominent advantages in the two major industries of ultra-high full-load operating temperature and ultra-wide constant power range. At the same time, high reliability, high efficiency, high power factor, high power density, wide output voltage range, low noise, low standby power consumption and good EMC performance are also the main characteristics of the ev charging module.

4,Standard configuration of CAN/RS485 communication interface, allows easy data transferring with external devices. and Low DC ripple causes minimum effects on the battery lifespan.MIDA EV charger module uses DSP (digital signal processing) control technology, and is fully numerically controlled from input to output.

    Model selection and the standard wiring

    30KW DC Charging Module

    Model No.

    UXR100040B

    AC Input

    Input Rating

    Rated voltage 380Vac, three phase (no center line), operating range 274-487Vac

    AC Input Connection

    3L + PE

    Input Frequency

    50±5Hz

    Input Power Factor

    ≥0.99

    Input Overvoltage Protection

    490±10Vac

    Input Undervoltage Protection

    270±10Vac

    DC Output

    Rated Output Power

    40kW

    Output Voltage Range

    200-1000Vdc

    Output Current Range

    0.5-67A

    Output Constant Power Range

    When output voltage is 300-1000Vdc, constant 30kW will output

    Peak Efficiency

    ≥ 96%

    Soft Start Time

    3-8s

    Short Circuit Protection

    Self-rollback protection

    Voltage Regulation Accuracy

    ≤±0.5%

    THD

    ≤5%

    Current Regulation Accuracy

    ≤±1%

    Current Sharing Imbalance

    ≤±5%

    Operation
    Environment

    Operating Temperature (°C)

    -40˚C ~ +75˚C, derating from 55˚C

    Humidity (%)

    ≤95% RH, non-condensing

    Altitude (m)

    ≤2000m, derating above 2000m

    Cooling method

    Fan cooling

    Mechanical

    Standby Power Consumption

    <10W

    Communication Protocol

    CAN

    Address Setting

    Digital screen display, keys operation

    Module Dimension

    437.5*300*84mm (L*W*H)

    Weight (kg)

    ≤ 15Kg

    Protection

    Input Protection

    OVP, OCP, OPP, OTP, UVP, Surge protection

    Output Protection

    SCP, OVP, OCP, OTP, UVP

    Electrical Insulation

    Insulated DC output and AC input

    MTBF

    500 000 hours

    Regulation

    Certificate

    UL2202, IEC61851-1, IEC61851-23, IEC61851-21-2 Class B

    Safety

    CE, TUV